Double-winding Latching Type (G6SK-2, G6SK-2F, G6SK-2G)
Rated voltage
|
3 VDC
|
4.5 VDC
|
5 VDC
|
12 VDC
|
24 VDC
|
Rated current
|
66.6 mA
|
44.4 mA
|
40 mA
|
16.7 mA
|
12.5 mA
|
Coil resistance
|
45 Ω
|
101 Ω
|
125 Ω
|
720 Ω
|
1,920 Ω
|
Must set voltage
|
75% max. of rated voltage
|
Must reset voltage
|
75% max. of rated voltage
|
Max. voltage
|
170% of rated voltage at 23ºC, 130% at 85ºC
|
140% of rated voltage at 23ºC, 110% at 70ºC
|
Power consumption
|
Approx. 200 mW
|
Approx. 300 mW
|
Note:
|
1.
|
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%.
|
|
2.
|
Operating characteristics are measured at a coil temperature of 23ºC.
|
|
3.
|
The maximum voltage is the highest voltage that can be imposed on the relay coil.
|
|
EN60950 certified Model (G6S-2F-Y, G6S-2G-Y, G6S-2-Y)
Rated voltage
|
5 VDC
|
12 VDC
|
24 VDC
|
Rated current
|
40 mA
|
16.7 mA
|
9.6 mA
|
Coil resistance
|
125 Ω
|
720 Ω
|
2,504 Ω
|
Must operate voltage
|
75% max. of rated voltage
|
Must release voltage
|
10% min. of rated voltage
|
Max. voltage
|
170% of rated voltage at 23ºC, 130% at 85ºC
|
170% of rated voltage at 23ºC, 110% at 70ºC
|
Power consumption
|
Approx. 200 mW
|
Approx. 230 mW
|
Note:
|
1.
|
The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%.
|
|
2.
|
Operating characteristics are measured at a coil temperature of 23ºC.
|
|
3.
|
The maximum voltage is the highest voltage that can be imposed on the relay coil.
|
|
Characteristics
Relay Function
|
Item
|
|
Single-side stable models
|
Single-winding latching models
|
Double-winding Latching
|
EN60950 certified
|
EN60950 certified
|
G6S-2, G6S-2F,
G6S-2G
|
G6SU-2, G6SU-2F,
G6SU-2G
|
G6SK-2, G6SK-2F,
G6SK-2G
|
G6S-2F-Y, G6S-2G-Y,
G6S-2-Y
|
G6SU-2-Y,
G6SU-2F-Y,
G6SU-2G-Y
|
Contact resistance *1
|
75 mΩ max.
|
Operating (set) time
|
4 ms max.
|
Release (reset) time
|
4 ms max.
|
Min. set/reset pulse width
|
---
|
10 ms
|
---
|
10 ms
|
Insulation resistance *2
|
100 M Ω min. (at 500 VDC)
|
Dielectric strength
|
Between coil and contacts
|
2,000 VAC, 50/60 Hz for 1 min
|
1,000 VAC, 50/60 Hz for 1 min
|
2,000 VAC, 50/60 Hz for 1 min
|
Between contacts of different polarity
|
1,500 VAC, 50/60 Hz for 1 min
|
Between contacts of the same polarity
|
1,000 VAC, 50/60 Hz for 1 min
|
Between set and reset coil
|
---
|
500 VAC, 50/60 Hz for 1 min
|
---
|
Impulse
withstand
voltage
|
Between coil and contacts
|
2,500 V (2 × 10 νs); 1,500 V (10 × 160 νs)
|
1,500 V (10 × 160 νs)
|
2,500 V (2 × 10 νs);
1,500 V (10 × 160 νs)
|
Between contacts of different polarity
|
2,500 V (2 × 10 νs); 1,500 V (10 × 160 νs)
|
Between contacts of the same polarity
|
1,500 V (10 × 160 νs)
|
Vibration resistance
|
Destruction
|
10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude)
|
Malfunction
|
10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude)
|
Shock resistance
|
Destruction
|
1,000 m/s2
|
Malfunction
|
750 m/s2
|
Durability
|
Mechanical
|
100,000,000 operations min. (at 36,000 operations/hr)
|
Electrical
|
100,000 operations min. for AC (at 1,800 operations/h with rated load)
100,000 operations min. for DC (at 1,200 operations/h with rated load)
|
Failure rate (P level) (reference value) *3
|
10 νA at 10 m VDC
|
Ambient operating temperature
|
-40°C
to 85°C (with no icing or condensation), and -40°C to 70°C (with no
icing or condensation) only for double-winding latching 24 VDC type and
EN60950 standard approved 24 VDC type
|
Ambient operating humidity
|
5% to 85%
|
Weight
|
Approx. 2 g
|
|